New Cybersecurity Collective: Sierra Nevada Corporation

Deck: 

Anterix

Fortnightly Magazine - February 2022

Harkening back to May 2020 when the FCC made a key segment of spectrum available for electric utilities to use for broadband data platforms to support the modern electric grid, private network users now will benefit from an Anterix cybersecurity collective. Anterix brought together a team of cyber-physical solutions providers to drive security around scads of connected equipment with deployment of 900 megahertz spectrum based private LTE. PUF talks here with members of the collective: Qubitekk's Corey McClelland and Scott Packard, Onclave Network's Scott Martin, and Sierra Nevada's Pete Fischer, to dig into these essential services. 
 

PUF's Steve Mitnick: What does Sierra Nevada Corporation do in the utilities industry?

Pete Fischer: We are primarily a defense contractor. We're a system integrator for the Department of Defense. That is Sierra Nevada Corporation's main business. You might have heard recently of Sierra Space, one of our big endeavors that actually spun off. We're not only in space, but we're also in the Department of Defense.

My cyber organization protects all of those industries and systems. We are responsible for protecting all of the critical infrastructure on the Department of Defense side. 

We got into the utility industry around 2014 because we saw vulnerabilities and gaps in that defense strategy. If you aren't protecting the infrastructure that feeds a base, like the power systems, because most of these bases use public utilities to power them, then you've got this big donut hole of security.

That's why we got into that business. We use a variety of our technology solutions and some of our techniques, but primarily it's Binary Armor. That's an edge cybersecurity tool for operational technology, or the equipment that the grid uses to operate. Think transformers, smart grid, all the equipment out in the field, what actually runs the grid, that's what Binary Armor does. 

To give you a quick example, it's in parallel to your utilities, but with what happened at Colonial Pipeline, a ransomware attack against them wouldn't have been a big deal had they not shut down the pipeline. They turned off the operational technology side, and the operations part, the things we care about.

With Binary Armor in place, you don't have to shut the operational technology off even if you get attacked because we provide inline cybersecurity that guarantees you are not going to be compromised. 

What we like to say is, hey, your organization might get attacked. Almost certainly U.S. utilities at some point will get hacked and they will get compromised. We'll keep the lights on. That's our job. We'll keep the grid functioning while you deal with other things.

PUF: Why is it called Binary Armor? What does it do?

Pete Fischer: There's a new term that's starting to hit the street. It's been around forever, but you and I will read about this in the news as SCADA, or supervisory control and data acquisition. 

Five years ago, you and I wouldn't be using that term, but that is the control system network that runs the operational technology. That is the backbone. They communicate mostly remotely to all these sites, and they're all networked together.

SCADA is the communications that they use. Binary Armor sits in between those systems you want to protect and the rest of the SCADA network, and it looks at everything going to and from those remote sites. It's what we call inline cybersecurity. We make sure that only safe commands go to those SCADA systems, and we make sure nothing unsafe goes back.

We've all heard about hardware implants of, "I'm going to go break into a substation. I'm going to go put in a little unsafe implant, and now I'm going to get onto the network and control everything." We make sure that nothing is going back that way.

We protect against that, as well as protect against people damaging the critical grid components. We're compared a lot of times to something like a firewall. What we do different is the level of protection. We're looking at everything going in and out.

In these advanced attacks, somebody might send you something that's actually okay to send, except they embed some bad commands, or they do things really frequently. They turn something on and off, on and off, on and off. Those types of things are unsafe, but they're all valid commands, and they're all allowed. They're just being used maliciously.

PUF: Do you have some experiences of working with utilities? What have been the positive experiences of working in that space?

Pete Fischer: Yes. In the utility space we've had a couple that I can talk to. One is, in smaller municipalities, we've found that a lot of these happen in rural co-ops, where they don't really have a cybersecurity defense. This gives bad actors or insider threats easy access.

The way we work, we map safe workflows customized to how you use these data systems. The nice thing there is, once you get Binary Armor configured and installed, you don't have to have an IT system to protect your SCADA systems. You're not looking at, what's the next threat? What is the next signature that I need to worry about?

You only allow what's good, and that doesn't change. By default, you're protecting against future threats. You're not sitting there having to stand up 24/7 monitoring, looking for all these threats and what's the next malware because you're already protecting the machines against everything except what's allowed and safe.

In the utility industry, the way you use your control systems, it doesn't change very often. It only changes when you add a new piece of equipment or build a new substation. That's one good example of getting robust security that doesn't have a big O&M cost to it, like a firewall or threat detection does.

Binary Armor is built for protecting these SCADA systems. It's designed to give them good protection without a huge cost and all the complexity of what people do for your email and websites. They're different worlds.

PUF: What would you say if you got a call from a utility and they say, we're interested in what you do, but we have several consulting firms working on cybersecurity. Can you fit into that? 

Pete Fischer: The answer is yes. That's a key to our success. We know that Binary Armor can't be difficult or highly proprietary. We have spent significant time making it so that it plays in the environment the customer wants. 

You drop Binary Armor in line, get it configured, you don't know it's there unless something bad is happening, and you're happy it's there. It'll integrate into everything you have. It'll integrate into what they call the security operations center or network operations center. For all of the IT folks, it'll feed data the way they want to.

It can be controlled just like all of our competitors. It has an enterprise management that we can give you, or it can be rolled up into something customers build themselves. 

The nicest thing, again, is from a configuration standpoint, you're not going to be standing up a team of Binary Armor engineers to manage, like you would for other products where you're sending people to classes all the time in order to keep their certifications up to date.

PUF: You're part of the Anterix security network, and they're pioneering and signing up a bunch of utilities for private networks. One of the main advantages is, it gives you opportunities for better security. How did you become part of Anterix?

Pete Fischer: In February of 2020, I was asked to be on a panel for the Edison Electric Institute on wildfire mitigation. Our technology helps with some of these ancillary use cases for utilities, not just for SCADA, but say you want to connect a sensor and you want that sensor to be able to go over public 4G LTE, and you want it to be safe.

We do that. We presented in the situational awareness area of how security might overlap, when you might want to take that into account, and gave some of the use cases we did. We got permission from one of our utilities, Hawaiian Electric, to show what we know with wildfire, because they're the first to have done this.

Anterix was there, and I met some of the folks. They were at a different stage in their maturity model. We kept in touch. Fast forward to today. When the opportunity hit, Anterix saw what we did on public and said, we'd love that kind of lockdown, tight security model available on our private networks.

The private network is fantastic, and it solves a lot of challenges for grid modernization. But it doesn't mean you don't still need security. Having a security overlay with that advancement is common sense.

The Anterix people are sharp. They see the next steps. Looking forward, they understand that need for SCADA cybersecurity. That's how we got into the collective. 


Cybersecurity Collective Super-Tech Company Profiles: